Off-grid solar and battery sizing for Weno
A 1 kW array in Weno produces about 1,492 kWh a year — but that annual figure is not what sizes a system. June is, and in June the same array makes only 3.7 kWh a day, against 4.6 in February.
What do you need?
Battery bank
12.9 kWh
268 Ah at 48V
Solar array
1.10 kW
about 3 panels of 450W
Summer only
0.89 kW
if you only use it February-ish
Sizing by household
Year-round systems in Weno, three days of autonomy, lithium.
| Use | Per day | Battery | Array | Panels |
|---|---|---|---|---|
| Weekend cabin LED lights, phone charging, a laptop, a small water pump |
1.0 kWh | 4.3 kWh | 0.37 kW | 1 |
| Basic off-grid living The above plus a small fridge and a few hours of television |
3.0 kWh | 12.9 kWh | 1.10 kW | 3 |
| Comfortable off-grid home Full-size fridge-freezer, washing machine, pumps, laptops |
6.0 kWh | 25.7 kWh | 2.20 kW | 5 |
| Everything except heating A normal household load, with heating and cooking on gas or wood |
10.0 kWh | 42.9 kWh | 3.66 kW | 9 |
Why June decides everything
Array needed to cover 3.0 kWh a day, month by month. The tallest bar is the one your system has to survive.
| Month | Yield per kW | Array needed | |
|---|---|---|---|
| January | 4.20 kWh/day | 0.97 kW | |
| February | 4.57 kWh/day | 0.89 kW | |
| March | 4.47 kWh/day | 0.91 kW | |
| April | 4.34 kWh/day | 0.94 kW | |
| May | 3.87 kWh/day | 1.05 kW | |
| June (worst) | 3.71 kWh/day | 1.10 kW | |
| July | 3.74 kWh/day | 1.09 kW | |
| August | 4.02 kWh/day | 1.01 kW | |
| September | 4.04 kWh/day | 1.01 kW | |
| October | 4.13 kWh/day | 0.99 kW | |
| November | 3.94 kWh/day | 1.03 kW | |
| December | 4.03 kWh/day | 1.01 kW |
What the numbers assume
- Battery capacity allows for inverter losses, round-trip efficiency, and a usable depth of discharge — 80% for lithium, 50% for lead-acid. Nameplate capacity is always larger than the energy you can actually use.
- Array size includes a 25% margin over the bare requirement. A system that exactly meets demand on an average day of June never recovers from a run of cloudy ones.
- Yield figures are measured, not modelled — PVGIS satellite and reanalysis data for 2005–2023, at the optimal angle for this location, with 14% system losses already deducted.
Limitations
- No shading. Trees, terrain and buildings are not modelled and can dominate everything here.
- Nothing about heating. Electric heating or cooking multiplies these figures several times over. Off-grid systems almost always use gas or wood for heat.
- Batteries age. Capacity falls over years; installers commonly oversize to allow for it.
- This is an estimate, not a design. A real installation needs a survey, local electrical regulations, and someone accountable for the result.