Off-grid solar and battery sizing for Auckland
A 1 kW array in Auckland produces about 1,233 kWh a year — but that annual figure is not what sizes a system. June is, and in June the same array makes only 1.5 kWh a day, against 5.2 in January.
What do you need?
Battery bank
12.9 kWh
268 Ah at 48V
Solar array
2.73 kW
about 7 panels of 450W
Summer only
0.78 kW
if you only use it January-ish
Sizing by household
Year-round systems in Auckland, three days of autonomy, lithium.
| Use | Per day | Battery | Array | Panels |
|---|---|---|---|---|
| Weekend cabin LED lights, phone charging, a laptop, a small water pump |
1.0 kWh | 4.3 kWh | 0.91 kW | 3 |
| Basic off-grid living The above plus a small fridge and a few hours of television |
3.0 kWh | 12.9 kWh | 2.73 kW | 7 |
| Comfortable off-grid home Full-size fridge-freezer, washing machine, pumps, laptops |
6.0 kWh | 25.7 kWh | 5.46 kW | 13 |
| Everything except heating A normal household load, with heating and cooking on gas or wood |
10.0 kWh | 42.9 kWh | 9.10 kW | 21 |
Why June decides everything
Array needed to cover 3.0 kWh a day, month by month. The tallest bar is the one your system has to survive.
| Month | Yield per kW | Array needed | |
|---|---|---|---|
| January | 5.22 kWh/day | 0.78 kW | |
| February | 4.42 kWh/day | 0.92 kW | |
| March | 3.67 kWh/day | 1.11 kW | |
| April | 2.65 kWh/day | 1.54 kW | |
| May | 1.87 kWh/day | 2.18 kW | |
| June (worst) | 1.49 kWh/day | 2.73 kW | |
| July | 1.68 kWh/day | 2.43 kW | |
| August | 2.31 kWh/day | 1.76 kW | |
| September | 3.23 kWh/day | 1.26 kW | |
| October | 4.14 kWh/day | 0.98 kW | |
| November | 4.86 kWh/day | 0.84 kW | |
| December | 5.06 kWh/day | 0.81 kW |
What the numbers assume
- Battery capacity allows for inverter losses, round-trip efficiency, and a usable depth of discharge — 80% for lithium, 50% for lead-acid. Nameplate capacity is always larger than the energy you can actually use.
- Array size includes a 25% margin over the bare requirement. A system that exactly meets demand on an average day of June never recovers from a run of cloudy ones.
- Yield figures are measured, not modelled — PVGIS satellite and reanalysis data for 2005–2023, at the optimal angle for this location, with 14% system losses already deducted.
Other cities in New Zealand
Limitations
- No shading. Trees, terrain and buildings are not modelled and can dominate everything here.
- Nothing about heating. Electric heating or cooking multiplies these figures several times over. Off-grid systems almost always use gas or wood for heat.
- Batteries age. Capacity falls over years; installers commonly oversize to allow for it.
- This is an estimate, not a design. A real installation needs a survey, local electrical regulations, and someone accountable for the result.